Valcourt Lafayette II Arched Wood Fireplace - FP10R
Free Shipping over $299
- FREE SHIPPING : All Over United States over $299
- SPEAK TO AN EXPERT : Call 888-486-2909 or email at cs@dreamwoodliving.com
Free Shipping over $299
The Valcourt Lafayette II Arched Wood Fireplace (FP10R) blends timeless elegance with advanced non-catalytic heating technology. Inspired by classic European design and upgraded with modern combustion engineering, this high-efficiency wood burning fireplace delivers powerful, consistent warmth while maintaining a refined arched façade. Designed for today’s homeowners, it offers clean-burning performance without sacrificing style, making it a standout built-in fireplace for both traditional and contemporary living spaces.
Fully customizable, the Lafayette II Arched features five faceplate louver options and decorative door overlays in black or brushed nickel to complement your décor. At 1.2 g/h of particulate emissions it is among the cleanest-burning wood fireplaces on the market — comfortably inside the EPA 2020 standard — and it heats 750 to 2,200 square feet from a 2.5 cubic foot firebox.
The Lafayette II FP10R needs a door overlay, a faceplate and a faceplate louver to be complete. Choose from each required group below.
Osburn and Valcourt are both built by SBI and share many parts, so some links below open our Osburn listing for the same part number.
Required – door overlay (choose one):
Required – faceplate:
Required – faceplate louver (choose one):
Optional:
| Maximum heat output (dry cordwood) | 80,000 BTU/h (23.4 kW) |
| Overall heat output range | 12,700 – 60,700 BTU/h (3.72 – 17.79 kW) |
| Recommended heating area | 750 – 2,200 sq ft (70 – 204 m²) |
| Average overall efficiency (HHV) | 64% |
| Average overall efficiency (LHV) | 68% |
| Optimum overall efficiency | 70% |
| Average particulate emissions | 1.2 g/h (EPA / CSA B415.1-10) |
| Average carbon monoxide | 98 g/h |
| Maximum burn time | 8 hours |
| Overall firebox volume | 2.5 cu ft (0.071 m³) |
| EPA loading volume | 1.94 cu ft (0.055 m³) |
| Recommended log length | 16" (406 mm), loaded east-west |
| Blower | Included, up to 176 CFM |
Give these to your builder before framing. Note the alternate widths — if you plan a fresh air intake or a forced air distribution kit, the framed opening has to be considerably wider for a centred installation, and that decision has to be made before the wall goes up:
| Framing width — standard | 37 3/4" (960 mm) |
| Framing width — with fresh air intake | 60 3/4" (1,543 mm) |
| Framing width — with forced air kit | 72 3/4" (1,848 mm) |
| Height to first header | 41 5/8" (1,057 mm) |
| Framing depth | 24 7/8" (632 mm) |
| Total framing height | 80" (2,032 mm) |
| Maximum mantel depth | 3" (76 mm) |
| Minimum mantel height above the door opening | 8" (203 mm) |
| Side wall, measured from the door opening | 13" (330 mm) |
| Minimum distance to the wall in front | 48" (122 cm) |
| Minimum ceiling height, measured from the base of the fireplace | 80" (2.03 m) |
| Enclosure — back, sides and floor beneath the fireplace | 0" (zero clearance) |
| Chimney clearance to combustibles | 2" (50 mm) |
| Minimum chimney height | 15' (4.6 m) from the base of the appliance to the chimney cap |
The 3" maximum mantel depth is the figure that most often catches people out on this model — a deeper decorative mantel shelf is not permitted above the opening.
| Specifications | Details |
| Combustion technology | Non-catalytic |
| High-efficiency certified appliance | Yes, EPA 2020 approved |
| Fuel type | Dry cordwood |
| Maximum log length | 20" |
| Log positioning | Loading over width |
| Chimney diameter | 6" |
| Flue outlet diameter | 6" |
| Type of chimney | UL 103 HT (2100 °F) |
| Minimum chimney height (feet) | 15' |
| Baffle type | C-Cast or equivalent |
| Approved for a mobile home installation | No |
| Shipping Weight | 493 lb (224 kg) |
| Door type | Single, glass with steel frame |
| Glass type | Ceramic glass |
| Glass surface – dimensions (Width X Height) | 24 3/8" x 12 5/8" |
| Glass air-wash system | Yes |
| Premium quality blower included (CFM) | 176 |
| Overall dimension (Height) | 40 5/8" |
| Overall dimension (Width) | 36 3/4" |
| Overall dimension (Depth) | 28 3/8" |
| Door opening – dimension (Height) | 10 1/2" |
| Door opening - dimension (Width) | 25 3/8" |
| Firebox – dimension (Height) | 12 1/8" |
| Firebox – dimension (Width) | 20 3/8" |
| Firebox – dimension (Depth) | 12 7/8" |
| Moulded refractory bricks | Yes |
| Stainless-steel secondary-air system improving gas combustion | Yes |
| USA standard (emissions) | EPA |
| USA standard (safety) | UL 127 |
| Tested and listed as per applicable standards | By an accredited laboratory |
| Warranty | Limited lifetime |