Empire Tahoe Clean Face Deluxe 42" Direct Vent Gas Fireplace - Millivolt
The Empire Tahoe Clean Face Deluxe 42" Direct Vent Gas Fireplace - Millivolt features Contour tube-style burner, designed to complement the hand-painted ceramic fiber log set, and produce a natural dancing flame.
The Empire Tahoe Clean Face Deluxe 42" Direct Vent Gas Fireplace - Millivolt comes with a discreet air distribution channel that eliminates the look of louvers, yet still allows you to operate the optional blower. It features a large heat-resistant, tempered glass window that provides an unobstructed view to the log set.
Choose an optional liner – Aged Brick, Herringbone, Stacked Limestone, or Black Reflective – to customize your fireplace.
Tahoe Clean-Face Deluxe models require 17-3/4" of depth, and use 4 x 6-5/8 venting, making them ideal for applications where wall-cavity space is tight.
Designed for in-wall installation, your Tahoe Direct-Vent fireplace can be finished with tile or other non-combustible material, which conceals the outer edge of the fireplace to provide a true built-in appearance.
Features
-
Tempered Glass: 22 x 36 1/2
-
Top or Rear Vent, Venting: 4 x 6 5/8
-
Framing: 41 H x 44 1/4 W x 18 D
- Variable Speed Blower available as an Accessory
- Includes:
- 7-piece Ceramic Fiber Log Set
- Fireplace Barrier Screen
- Optional Remotes
- Weight: 127.00 lbs
What to Order With It
The log set is included with the fireplace. Apart from venting, everything below is optional.
Optional – Remotes and wall controls:
-
Remote, Battery Receiver/Remote, On/Off (FRBC)
-
Remote, Battery Receiver/Remote, Thermostat (FRBTC2)
-
Remote, Electric Receiver/Battery Remote, On/Off (FREC)
-
Remote, Battery Receiver/Remote, TouchScreen, Programmable (FRBTPS)
-
Wall Switch, On/Off (FWS1)
-
Wall Thermostat, Reed Switch (TMV)
-
Wall Thermostat, Wireless (TRW)
Optional – Accessories:
Optional – Liners:
Optional – Gas conversion kits:
Installation Requirements
-
Clearances to combustibles: Back 0", sides 0", floor 0", top standoffs 0", top framing edge 0"; minimum 41" from top of canopy to ceiling; 6" from side of fireplace to an adjacent side wall
-
Mantel clearance: Follow the mantel chart in the installation manual for any combustible mantel above the unit.
-
Venting: 4" x 6-5/8" direct vent, top or rear; maximum 40 ft vertical and 20 ft horizontal (see the venting graphs in the installation manual for allowed combinations)
-
Gas input (BTU/hr): Natural gas 25,000 max / 18,000 min; propane 25,000 max / 19,500 min
-
Power: Millivolt models (FP30, FP31) need no electricity to run the burner. The blower requires 120V, 60Hz, 1 amp.
-
Installation: Must be installed by a qualified installer per the installation manual and local codes.
Downloads
/